Appboard/2.4/builder/data sources/third party/omnibus: Difference between revisions
imported>Jason.nicholls (→Query) |
imported>Jason.nicholls No edit summary |
||
Line 9: | Line 9: | ||
=== Configure Connection Settings === | === Configure Connection Settings === | ||
The table below details the settings you can configure for a <b>Tivoli Netcool/ | The table below details the settings you can configure for a <b>Tivoli Netcool/OMNIbus</b> Data Source: | ||
{|class="wikitable" | {|class="wikitable" | ||
Line 16: | Line 16: | ||
|- | |- | ||
|'''host''' | |'''host''' | ||
| The hostname or IP address referring to the Netcool/ | | The hostname or IP address referring to the Netcool/OMNIbus database. | ||
|- | |- | ||
|'''port''' | |'''port''' | ||
| The TCP port of the Netcool/ | | The TCP port of the Netcool/OMNIbus database. Default value is <tt>4100</tt>. | ||
|- | |- | ||
|'''dbname''' | |'''dbname''' | ||
| The name of the Netcool/ | | The name of the Netcool/OMNIbus database. Default value: <tt>NCOMS</tt> | ||
|- | |- | ||
|'''connectTimeout''' | |'''connectTimeout''' |
Revision as of 08:38, 24 October 2013
This page provides details for configuring IBM Tivoli Netcool/OMNIbus adapters in AppBoard. This data adapter retrieves information directly from an OMNIbus ObjectServer.
In many cases, you will want to pass a parameter value into a query rather than using a static query definition. AppBoard provides a system of variable expressions, called SHIM, that can be used for this purpose. For instructions on this option, see SHIM Expressions.
Data Source Configuration
Configure Connection Settings
The table below details the settings you can configure for a Tivoli Netcool/OMNIbus Data Source:
Name | Description |
---|---|
host | The hostname or IP address referring to the Netcool/OMNIbus database. |
port | The TCP port of the Netcool/OMNIbus database. Default value is 4100. |
dbname | The name of the Netcool/OMNIbus database. Default value: NCOMS |
connectTimeout | Time (in seconds) to wait for the host to respond before abandoning the establishment of a connection to a datasource. If there is latency between AppBoard and the database, due to network configuration, this value may need to be increased. |
timeout | Time to wait (in seconds) to wait before abandoning the retrieval of a new connection from the datasource. In the case that a great number of connections are made to this host, the size of the pool may need to be increased as a timeout typically indicates that the pool is exhausted and are waiting for a new connection "slot" to become available. |
username | User name credential used to connect to database. |
password | User password credential used to connect to database. |
Query
You can configure one or more queries in each Netcool/OMNIbus adapter configuration. Each configured query will have a different name, and result in a different Data Collection with that name. When naming a query, only alphanumeric characters, underscores, and hyphens are permitted.
Queries - Entity Settings Screen:
Name | Description |
---|---|
Name | Name of this SQL query entity. Note: if editing the name all references internal to AppBoard are updated automatically, however in some cases Data Processing Scripts may have hardcoded references that will break as a result of the rename. In cases where AppBoard can detect this an error message is presented to the administrator identifying the affected scripts. |
Description | A summary of the purpose of the query and any details or notes to provide for the system administrator |
Cache Timeout (seconds) | Maximum time a response from the database is kept before discarding. |
SQL Query | SQL statement defining the records to be returned by the query |
Data Processing Script(s) | List of one or more Data Processing Scripts to be run on the query. |